施工现场临时用电各级配电箱 配电系统图
漏电动作电流100mA/ D220L-220/4300 进线
PE
接A支箱Ⅰ 级箱(400A) N
N
接B支箱Ⅰ级箱(630A)
接C支箱Ⅰ级箱(630A)
接D支箱Ⅰ级箱(400A)
HK60/380
PZ NM-100/3300 8#塔吊(120A) HK60/380
PZ NM-100/3300 8#施工电梯(90A) HK30/380
NM-100/3300 4#、8#钢筋加工区(40A)
HK30/220
NM-100/3300 生活区用电(90A)
HK60/380
NM-100/3300 8#楼层及地下室(30A)
HK30/380
NM-100/3300 备用(30A)
A一级箱
HK60/380
PZ NM-100/3300 4#塔吊(90A) HK60/380
PZ NM-100/3300 4#施工电梯(90A) HK30/380
NM-100/3300 3#施工电梯(90A)
HK30/380
NM-100/3300 钢筋加工区(60A)
HK60/380
NM-100/3300 3#楼层及地下室(60A)
HK30/380
NM-100/3300 4#楼层及地下室(60A)
HK30∕380
NM-100∕3300 2#楼层及地下室(60A)
HK30∕380
NM-100∕3300 备用(60A) HK30∕380
NM-100∕3300 备用(60A)
B一级箱
HK60/380
PZ NM-100/3300 1#塔吊(90A) HK60/380
PZ NM-100/3300 1#施工电梯(90A) HK30/380
NM-100/3300 2#施工电梯(90A)
HK30/380
NM-100/3300 2#塔吊(90A)
HK60/380
NM-100/3300 5#塔吊(90A)
HK30/380
NM-100/3300 5#施工电梯(90A)
HK30∕380
NM-100∕3300 1#楼层及地下室(30A)
HK30∕380
NM-100∕3300 备用(30A) HK30∕380
NM-100∕3300 备用(30A)
C一级箱
HK60/380
PZ NM-100/3300 7#塔吊(90A) HK60/380
PZ NM-100/3300 7#施工电梯(90) HK30/380
NM-100/3300 6#施工电梯(90)
HK30/380
NM-100/3300 5#楼层及地下室(30)
HK60/380
NM-100/3300 6#楼层及地下室(50)
HK30/380
NM-100/3300 7#楼层及地下室(50)
D 一级箱