ADuM1400/ADuM1401/ADuM1402

DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS

Data Sheet

These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval. Table 11.

Description

Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms For Rated Mains Voltage ≤ 300 V rms For Rated Mains Voltage ≤ 400 V rms Climatic Classification

Pollution Degree per DIN VDE 0110, Table 1 Maximum Working Insulation Voltage Input to Output Test Voltage, Method B1 Input to Output Test Voltage, Method A After Environmental Tests Subgroup 1 After Input and/or Safety Test Subgroup 2 and Subgroup 3

Highest Allowable Overvoltage Safety Limiting Values Case Temperature Side 1 Current Side 2 Current

Insulation Resistance at TS

350300Conditions Symbol Characteristic Unit I to IV I to III I to II

40/105/21 2 560 1050

VIORM × 1.875 = VPR, 100% production test, tm = 1 sec, partial discharge < 5 pC

VIORM × 1.6 = VPR, tm = 60 sec, partial discharge < 5 pC VIORM × 1.2 = VPR, tm = 60 sec, partial discharge < 5 pC Transient overvoltage, tTR = 10 seconds

Maximum value allowed in the event of a failure (see Figure 4)

VIORM VPR VPR

V peak V peak

6 672

VTR

4000

V peak V peak V peak

VIO = 500 V

TS IS1 IS2 RS 150 265 335 >109°C mA mA Ω

RECOMMENDED OPERATING CONDITIONS

Table 12.

SIDE #2SAFETY-LIMITING CURRENT (mA)250200150SIDE #1100500Parameter

Operating Temperature (TA)1 Operating Temperature (TA)2 Supply Voltages (VDD1, VDD2)1, 3 Supply Voltages (VDD1, VDD2)2, 3 Input Signal Rise and Fall Times

1

Rating

−40°C to +105°C −40°C to +125°C 2.7 V to 5.5 V 3.0 V to 5.5 V 1.0 ms

050100150CASE TEMPERATURE (°C)200Figure 4. Thermal Derating Curve, Dependence of Safety Limiting Values

with Case Temperature per DIN V VDE V 0884-10

Does not apply to ADuM1400W, ADuM1401W, and ADuM1402W automotive grade versions. 2

Applies to ADuM1400W, ADuM1401W, and ADuM1402W automotive grade versions. 3

All voltages are relative to their respective ground. See the DC Correctness and Magnetic Field Immunity section for information on immunity to external magnetic fields.

03786-004Rev. L | Page 20 of 31

Data Sheet

ABSOLUTE MAXIMUM RATINGS

Ambient temperature = 25°C, unless otherwise noted. Table 13.

Parameter

Storage Temperature (TST)

Ambient Operating Temperature (TA)1 Ambient Operating Temperature (TA)2 Supply Voltages (VDD1, VDD2)3

Input Voltage (VIA, VIB, VIC, VID, VE1, VE2)3, 4 Output Voltage (VOA, VOB, VOC, VOD)3, 4 Average Output Current per Pin5 Side 1 (IO1) Side 2 (IO2)

Common-Mode Transients6

1

ADuM1400/ADuM1401/ADuM1402

Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended periods may affect product reliability.

Rating

−65°C to +150°C −40°C to +105°C −40°C to +125°C −0.5 V to +7.0 V −0.5 V to VDDI + 0.5 V −0.5 V to VDDO + 0.5 V −18 mA to +18 mA −22 mA to +22 mA

−100 kV/µs to +100 kV/µs

ESD CAUTION

Does not apply to ADuM1400W, ADuM1401W, and ADuM1402W automotive grade versions. 2

Applies to ADuM1400W, ADuM1401W, and ADuM1402W automotive grade versions. 3

All voltages are relative to their respective ground. 4

VDDI and VDDO refer to the supply voltages on the input and output sides of a given channel, respectively. See the PC Board Layout section. 5

See Figure 4 for maximum rated current values for various temperatures. 6

This refers to common-mode transients across the insulation barrier. Common-mode transients exceeding the Absolute Maximum Ratings may cause latch-up or permanent damage.

Table 14. Maximum Continuous Working Voltage1

Parameter

AC Voltage, Bipolar Waveform AC Voltage, Unipolar Waveform Basic Insulation

Reinforced Insulation DC Voltage

Basic Insulation

Reinforced Insulation

1

Max 565 1131 560 1131 560

Unit V peak V peak V peak V peak V peak

Constraint

50-year minimum lifetime

Maximum approved working voltage per IEC 60950-1

Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10 Maximum approved working voltage per IEC 60950-1

Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10

Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.

Table 15. Truth Table (Positive Logic)

VIx Input1 H L X X X X

VEx Input1, 2 H or NC H or NC L

H or NC L X

VDDI State1 Powered Powered Powered Unpowered Unpowered Powered

VDDO State1 Powered Powered Powered Powered Powered Unpowered

VOx Output1 Notes H L Z H Outputs return to the input state within 1 µs of VDDI power restoration. Z

Indeterminate Outputs return to the input state within 1 µs of VDDO power restoration

if the VEx state is H or NC. Outputs return to a high impedance state within 8 ns of VDDO power restoration if the VEx state is L.

VIx and VOx refer to the input and output signals of a given channel (A, B, C, or D). VEx refers to the output enable signal on the same side as the VOx outputs. VDDI and VDDO refer to the supply voltages on the input and output sides of the given channel, respectively. 2

In noisy environments, connecting VEx to an external logic high or low is recommended.

1

Rev. L | Page 21 of 31